2 Parameters
2.2 List of parameters
SINAMICS DCP
302 List Manual (LH21), 05/2016
Description: Display and connector output for the reactor current of power unit 3.
Dependency: Refer to: r55510
Description: Sets the internal resistance of the voltage source connected at side 1.
The setting value for this parameter is referred to the rated device quantities (rated voltage, rated current)
p55515 = Ri * I_rated/U_rated
Ri:
Internal resistance of the voltage source connected at side 1.
Description: Sets the internal resistance of the voltage source connected at side 2.
The setting value for this parameter is referred to the rated device quantities (rated voltage, rated current)
p55516 = Ri * I_rated/U_rated
Ri:
Internal resistance of the voltage source connected at side 2.
Description: Sets the smoothing time constant in the voltage actual value channel.
Index: [0] = Side 1
[1] = Side 2
Description: Display and connector output for the sum of the averaged reactor currents.
The value is the sum of r55521, r55522 and r55523.
Dependency: Refer to: r55521, r55522
r55513 CO: Actual value reactor current power unit 3 / ActVal I_react PU3
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [%] - [%] - [%]
p55515 Resistance inner side 1 / R inner S1
DCP_CTRL Can be changed: U, T Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
0.00 [%] 20.00 [%] 0.00 [%]
p55516 Resistance inner side 2 / R inner S2
DCP_CTRL Can be changed: U, T Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
0.00 [%] 20.00 [%] 0.00 [%]
p55518[0...1] Voltage actual value smoothing time constant / U_act T
DCP_CTRL Can be changed: U, T Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
0.00 [ms] 1000.00 [ms] 100.00 [ms]
r55520 CO: Actual value reactor current sum averaged / ActVal I_re SumAvg
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [%] - [%] - [%]