2 Parameters
2.2 List of parameters
Description: Sets the signal source for the output value at analog output 0 (AO 0, X177.49/50).
Note: AO: Analog Output
Description: Sets the mode for signal processing at analog output 0 (AO 0, X177.49/50).
Value: 0: Signal not influenced
1: Signal absolute value generation
2: Signal inverted
3: Signal absolute value generation inverted
Note: AO: Analog Output
Description: Sets the time constant for smoothing the signal from analog output 0 (AO 0, X177.49/50).
Note: AO: Analog Output
Description: Sets the scaling for analog output 0 (AO 0, X177.49/50).
The value indicates the output value for mapping an input value of 100% at the analog output.
Note: AO: Analog Output
Description: Sets the offset for analog output 0 (AO 0, X177.49/50).
Note: AO: Analog Output
Description: Sets the signal source for the output value at analog output 1 (AO 1, X177.51/52).
Note: AO: Analog Output
p50750 CI: CUD analog output 0 signal source / CUD AO 0 s_src
DCP_CTRL Can be changed: U, T Access level: 3
Data type: Unsigned32 / FloatingPoint32 Func. diagram: 2095
Min Max Factory setting
- - 0
p50751 CUD analog output 0 signal processing / CUD AO 0 sig proc
DCP_CTRL Can be changed: U, T Access level: 3
Data type: Integer16 Func. diagram: 2095
Min Max Factory setting
0 3 0
p50752 CUD analog output 0 smoothing time constant / CUD AO 0 T
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 2095
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50753 CUD analog output 0 scaling / CUD AO 0 scal
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 2095
Min Max Factory setting
-200.00 [V] 200.00 [V] 10.00 [V]
p50754 CUD analog output 0 offset / CUD AO 0 offs
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 2095
Min Max Factory setting
-10.00 [V] 10.00 [V] 0.00 [V]
p50755 CI: CUD analog output 1 signal source / CUD AO 1 s_src
DCP_CTRL Can be changed: U, T Access level: 3
Data type: Unsigned32 / FloatingPoint32 Func. diagram: 2095
Min Max Factory setting
- - 0