Siemens sinamics dcp - r55521 CO: Actual value reactor current power unit 1 averaged; ActVal I_re PU1 avg; r55522 CO: Actual value reactor current power unit 2 averaged; ActVal I_re PU2 avg; r55523 CO: Actual value reactor current power unit 3 averaged; ActVal I_re PU3 avg; p55525 Actual value current offset adjustment; ActVal I offs adj

Siemens sinamics dcp
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCP
List Manual (LH21), 05/2016
303
2 Parameters
2.2 List of parameters
Description: Display and connector output for the averaged reactor current of power unit 1.
Dependency: Refer to: r55520
Description: Display and connector output for the averaged reactor current of power unit 2.
Dependency: Refer to: r55520
Description: Display and connector output for the averaged reactor current of power unit 3.
Dependency: Refer to: r55520
Description: Sets the offset for the "local" adjustment of the current actual value.
Description: Sets the gain for the "local" adjustment of the current actual value.
Description: Displays the sum of the averaged reactor currents.
The value is the sum of r55531, r55532 and r55533.
Dependency: Refer to: r55531, r55532
r55521 CO: Actual value reactor current power unit 1 averaged / ActVal I_re PU1avg
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [%] - [%] - [%]
r55522 CO: Actual value reactor current power unit 2 averaged / ActVal I_re PU2avg
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [%] - [%] - [%]
r55523 CO: Actual value reactor current power unit 3 averaged / ActVal I_re PU3avg
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [%] - [%] - [%]
p55525 Actual value current offset adjustment / ActVal I offs adj
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
-5.00 [%] 5.00 [%] 0.00 [%]
p55526 Actual value current gain adjustment / ActVal I gain adj
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
-5.00 [%] 5.00 [%] 0.00 [%]
r55530 Actual value reactor current sum averaged / ActVal I_re SumAvg
DCP_CTRL Can be changed: - Access level: 1
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [A] - [A] - [A]