2 Parameters
2.2 List of parameters
Dependency: Refer to: r4023
Note: DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
Description: Displays the inverted status of the digital inputs of Terminal Module 15 (TM15).
Dependency: Refer to: r4022, r4024, r4025
Notice: For the BICO interconnection of the connector output (CO) only bit 00 ... 15 are transferred.
Note: DI/DO: Bidirectional Digital Input/Output
Description: Displays the inverted status of the digital inputs of Terminal Module 31 (TM31).
r4023.0...23 CO/BO: TM15DI/DO digital inputs status inverted / TM15D DI stat inv
TM15DI_DO Can be changed: - Access level: 1
Data type: Unsigned32 Func. diagram: 9399, 9400,
9401, 9402
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI/DO 0 (X520.2) High Low -
01 DI/DO 1 (X520.3) High Low -
02 DI/DO 2 (X520.4) High Low -
03 DI/DO 3 (X520.5) High Low -
04 DI/DO 4 (X520.6) High Low -
05 DI/DO 5 (X520.7) High Low -
06 DI/DO 6 (X520.8) High Low -
07 DI/DO 7 (X520.9) High Low -
08 DI/DO 8 (X521.2) High Low -
09 DI/DO 9 (X521.3) High Low -
10 DI/DO 10 (X521.4) High Low -
11 DI/DO 11 (X521.5) High Low -
12 DI/DO 12 (X521.6) High Low -
13 DI/DO 13 (X521.7) High Low -
14 DI/DO 14 (X521.8) High Low -
15 DI/DO 15 (X521.9) High Low -
16 DI/DO 16 (X522.2) High Low -
17 DI/DO 17 (X522.3) High Low -
18 DI/DO 18 (X522.4) High Low -
19 DI/DO 19 (X522.5) High Low -
20 DI/DO 20 (X522.6) High Low -
21 DI/DO 21 (X522.7) High Low -
22 DI/DO 22 (X522.8) High Low -
23 DI/DO 23 (X522.9) High Low -
r4023.0...11 CO/BO: TM31 digital inputs status inverted / TM31 DI status inv
TM31 Can be changed: - Access level: 1
Data type: Unsigned32 Func. diagram: 9549, 9550,
9552, 9560, 9562
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X520.1) High Low -
01 DI 1 (X520.2) High Low -
02 DI 2 (X520.3) High Low -
03 DI 3 (X520.4) High Low -
04 DI 4 (X530.1) High Low -
05 DI 5 (X530.2) High Low -
06 DI 6 (X530.3) High Low -
07 DI 7 (X530.4) High Low -
08 DI/DO 8 (X541.2) High Low -
09 DI/DO 9 (X541.3) High Low -
10 DI/DO 10 (X541.4) High Low -
11 DI/DO 11 (X541.5) High Low -
Siemens Parts