4 Faults and alarms
4.2 List of faults and alarms
SINAMICS DCP
396 List Manual (LH21), 05/2016
Fault value (r0949, interpret hexadecimal):
Method ID.
Note:
Only for internal Siemens troubleshooting.
Remedy: Contact the Hotline.
F01056 CU: Internal error (clock cycle of parameter group already assigned differently)
Drive object: DCP_CTRL, TM150
Cause: The requested parameter group (IREG, NREG, ...) is already being used in a different clock cycle.
Fault value (r0949, interpret hexadecimal):
Method ID.
Note:
Only for internal Siemens troubleshooting.
Remedy: Contact the Hotline.
F01057 CU: Internal error (different DRIVE-CLiQ type for the slave)
Drive object: DCP_CTRL, TM150
Cause: The requested DRIVE-CLiQ type (hps_ps, hps_enc, ...) has been specified differently for the same slave component.
Fault value (r0949, interpret hexadecimal):
Method ID.
Note:
Only for internal Siemens troubleshooting.
Remedy: Contact the Hotline.
F01058 CU: Internal error (slave missing in topology)
Drive object: DCP_CTRL, TM150
Cause: The requested slave component does not exist in the topology.
Fault value (r0949, interpret hexadecimal):
Method ID.
Note:
Only for internal Siemens troubleshooting.
Remedy: Contact the Hotline.
F01059 CU: Internal error (port does not exist)
Drive object: DCP_CTRL, TM150
Cause: The port object assigned according to the topology of the requested slave component does not exist.
Fault value (r0949, interpret hexadecimal):
Method ID.
Note:
Only for internal Siemens troubleshooting.
Remedy: Contact the Hotline.
F01060 CU: Internal error (parameter group not available)
Drive object: DCP_CTRL, TM150
Cause: The requested parameter group (IREG, NREG, ...) is not offered by this slave type.
Fault value (r0949, interpret hexadecimal):
Method ID.
Note:
Only for internal Siemens troubleshooting.
Remedy: Contact the Hotline.
F01061 CU: Internal error (application not known)
Drive object: DCP_CTRL, TM150
Cause: An application that is not registered with TSM has attempted to register with registerSlaves().
The cause can be an unsuccessful TSM registration or an incorrect registration sequence. It is always necessary to
log in to the TSM before registerSlaves() can be used.