SINAMICS DCP
List Manual (LH21), 05/2016
305
2 Parameters
2.2 List of parameters
For index 4:
P = U2 * I_ext (I_ext = value according to p55156)
The power is calculated from the voltage measured at side 2 and the externally measured current at side 2.
The result is the power that is either issued or fed in at side 2.
For index 3 ... 4:
These indices only supply sensible values if there is an external current measurement at the appropriate side and
p55156 is correspondingly set.
Description: Display and connector output for the actual value of the current at side 1.
Note: The current actual value sensing in SINAMICS DCP measures the reactor current.
The current at side 1 is calculated from the reactor current actual value.
If U1 <= U2:
- current at side 1 = reactor current actual value.
If U1 > U2:
- current at side 1 = reactor current actual value * U2/U1.
Explanation:
U1: voltage at side 1
U2: voltage at side 2
All values are referred to rated device quantities (rated current, rated voltage, rated power).
Description: Display and connector output for the actual value of the current at side 2.
Note: The current actual value sensing in SINAMICS DCP measures the reactor current.
The current at side 2 is calculated from the reactor current actual value.
If U1 <= U2:
- current at side 2 = reactor current actual value * U1/U2.
If U1 > U2:
- current at side 2 = reactor current actual value.
Explanation:
U1: voltage at side 1
U2: voltage at side 2
All values are referred to rated device quantities (rated current, rated voltage, rated power).
Description: Display of the actual value for the current at side 1.
Dependency: Refer to: r55541
r55541 CO: Actual value current side 1 / Act val I_S1
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [%] - [%] - [%]
r55542 CO: Actual value current side 2 / Act val I_S2
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [%] - [%] - [%]
r55543 Actual value current side 1 / Act val I_S1
DCP_CTRL Can be changed: - Access level: 1
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [A] - [A] - [A]