SINAMICS DCP
List Manual (LH21), 05/2016
365
3 Function diagrams
3.10 Signals and monitoring functions
Fig. 3-44 8048 – Monitoring functions in the device
fp_8048_89.vsd
12345678
- 8048 -
SINAMICS DCP
25.04.2016 v 1.2
DO: DCP_CTRL
- Monitoring functions in the device
Function diagram
Note:
The temperature sensors are monitored for wire breaks and F60096 is triggered if necessary.
8,000 μs
[1020.7]
+
Temperature sensor
on the CUD module
 > 95°
 > 90°
F60090
Fault CUD temp exc
A60081
Alarm CUD temp exc
+
F60091
P10 outside tol
F60092
N10 outside tol
Supply voltage
 > Schwelle
 > Schwelle -5°
 > Schwelle
 > Schwelle -5°
+
+
+
+
F60067
Fault PU temp exc
A60080
Alarm PU temp exc
F60067
Fault PU temp exc
A60080
Alarm PU temp exc
Temperature sensor 1
Temperature sensor 2
P10
N10
Abweichung > ± 5%
Abweichung > ± 5%
+
+
Electr supp U_disp
r50823[0]
Electr supp U_disp
r50823[1]
P5
P15
F60093
P5 overload
F60094
P15 overload
X202
X202
+
Temperature sensor
on the mainboard module
 > 95°
 > 90°
F60521
Flt mod_temp exceeded
A60520
Alarm mod_temp exceed
+
+
r52050[2]
Temperature sensor
on the power supply module
 > 95°
 > 90°
F60521
Flt mod_temp exceeded
A60520
Alarm mod_temp exceed
+
 > Schwelle
 > Schwelle -5°
+
+
F60067
Fault PU temp exc
A60080
Alarm PU temp exc
Temperature sensor 3
X202
p55101[1]
Reduce temp_thresh
p55101[1]
Reduce temp_thresh
p55101[1]
Reduce temp_thresh
r52050[4]
Temp CUD Ctrl Unit
r52050[3]
Mainboard temp
r52050[6]
Temp PU3
r52050[1]
Temp PU2
r52050[0]
Temp PU1
r52051[0]
r52051[1]
r52051[2]
F60097
Power supply unit fault
=
=