Page #427 background imageLoading...
Page #427 background image
Send document comments to nexus7k-feedback-doc@cisco.com
2-389
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
MODULE Messages
Error Message MODULE-2-MOD_SOMEPORTS_FAILED: Module [dec] (serial: [chars])
reported failure on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in
device [dec] (error [hex])
Explanation Module [decimal digit] reported a failure in the runtime diagnostic due to failure in
some of the ports.
Recommended Action Collect information about the module by issuing the command 'show module
internal all module [decimal digit]'.
Error Message MODULE-2-MOD_UNKNOWN: Module type [[dec]] in slot [dec] is not
supported
Explanation The software card id of module [decimal digit] is not supported by the supervisor.
Recommended Action Collect information about the module by issuing the commands 'show module
internal all module [decimal digit]'.
Error Message MODULE-2-XBAR_DIAG_FAIL: Xbar [dec] (serial: [chars]) reported
failure [chars] due to [chars] in device [dec] (device error [hex])
Explanation The xbar in slot [decimal digit] reported a failure in the runtime diagnostic. Module
manager is going to power cycle the module.
Recommended Action Collect information about the module by issuing the command 'show module
internal all xbar [decimal digit]'.
Error Message MODULE-2-XBAR_FAIL: Initialization of xbar [dec] (serial: [chars])
failed
Explanation Xbar [decimal digit] reported a failure during the initialization phase and will be
powered down.
Recommended Action Collect information about the module by issuing the commands 'show
module_internal all xbar <module number>'.
Error Message MODULE-2-XBAR_SOMEPORTS_FAILED: Xbar [dec] (serial: [chars]) reported
failure on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec]
(error [hex])
Explanation Xbar [decimal digit] reported a failure in the runtime diagnostic due to failure in some
of the ports.
Recommended Action Collect information about the module by issuing the command 'show module
internal all xbar [decimal digit]'.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals