PLATFORM Messages
Error Message PLATFORM-2-MOD_PWRIDPROM_SW_CARD_ID_UNKNOWN: Module [dec] failed to
power up. (Unknown card. Could not get software-card-id)
Explanation The module cannot be powered because the missing SWID in core-plugin for thiscard
ID.
Recommended Action Enter a 'show platform internal all module [decimal digit]' and 'show module
internal all module [decimal digit]' 'show sprom module [dec] [dec]' to read module IDPROM
contents to collect more information.
Error Message PLATFORM-2-MOD_PWRIDPROM_SW_CARD_ID_UNKNOWN: Module [dec] failed to
power up. Couldnt get SWID (from CARDID) in core_plugin
Explanation The module cannot be powered because the missing SWID in core-plugin for thiscard
ID.
Recommended Action Enter a 'show platform internal all module [decimal digit]' and 'show module
internal all module [decimal digit]' 'show sprom module [dec] [dec]' to read module IDPROM
contents to collect more information.
Error Message PLATFORM-2-MOD_PWRIDPROMFAIL: Module [dec] failed to power up due to
IDPROM read error
Explanation The module cannot be powered because the IDPROM read error.
Recommended Action Enter a 'show platform internal all module [decimal digit]' and 'show module
internal all module [decimal digit]' 'show sprom module [dec] [dec]' to read module IDPROM
contents to collect more information.
Error Message PLATFORM-2-MOD_PWRUP: Module [dec] powered up (Serial number [chars])
Explanation The module in slot [decimal digit] is powered up.
Recommended Action No action is required.
Error Message PLATFORM-2-MOD_PWRUP_XBAR: Modules powered up due to xbar
availability
Explanation Modules powered up because at least one xbar module is online.
Recommended Action No action needed.
Error Message PLATFORM-2-MOD_REMOVE: Module [dec] removed (Serial number [chars])
Explanation The module in slot [decimal digit] has been removed.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals