PLATFORM Messages
Error Message PLATFORM-2-MOD_TEMPMAJOR_OK: [chars] recovered from major temperature
alarm. Sensor=[dec] Temperature=[dec] MajThreshold=[dec]
Explanation Module in slot [decimal digit] major temperature threshold.
Recommended Action Enter a 'show env temperature' to collect more information.
Error Message PLATFORM-2-MOD_TEMPMINALRM: [chars] reported minor temperature alarm.
Sensor=[dec] Temperature=[dec] MinThreshold=[dec]
Explanation Module in slot [decimal digit] has exceeded mior temperature threshold.
Recommended Action Enter a 'show env temperature' to collect more information.
Error Message PLATFORM-2-MOD_TEMPOK: [chars] recovered from minor temperature
alarm. Sensor=[dec] Temperature=[dec] MinThreshold=[dec]
Explanation Module in slot [decimal digit] mior temperature threshold.
Recommended Action Enter a 'show env temperature' to collect more information.
Error Message PLATFORM-2-MOD_TEMPRECOVER: [chars] recovered from major temperature
alarm. Minor temperature alarm pending. Sensor=[dec] Temperature=[dec]
MajThreshold=[dec] MinThresh=[dec]
Explanation Module in slot [decimal digit] recovered from major temperature threshold. Minor
threshold still exceeded.
Recommended Action Enter a 'show env temperature' to collect more information.
Error Message PLATFORM-2-PFM_CRITICAL: [chars]
Explanation Platform Critical.
Recommended Action No action is required.
Error Message PLATFORM-2-PFM_FATW_BUS_SWITCH: Backplane two wire [chars] bus
connection fault caused bus switchover(BUS_A to BUS_B)
Explanation Could not access some modules using BUS_A, but can access using BUS_B.
Recommended Action Enter a 'show platform internal error'.
Error Message PLATFORM-2-PFM_FATW_BUS_SWITCH: Backplane two wire [chars] bus
connection or device fault caused bus switchover(BUS_A to BUS_B)
Explanation Could not access some modules using BUS_A, but can access using BUS_B.
Recommended Action Enter a 'show platform internal error'.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals