2-487
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message PLATFORM-2-PS_AC_IN_MISSING: Power supply [dec] present but all AC
inputs are not connected, ac-redundancy might be affected
Explanation Power Supply is present but not at full capacity.
Recommended Action No action is required.
Error Message PLATFORM-2-PS_CAP_CHG: AC Input insertion/removal detected for power
supply [dec]. This might results in change of total power available.
Explanation AC input cable has been plugged in/out or AC input power has been restoreddd/lost.
Recommended Action Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information. Refer to power supply document
on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PLATFORM-2-PS_CAPACITY_CHANGE: Power supply PS[dec] changed its
capacity. possibly due to power cable removal/insertion (Serial number [chars])
Explanation Detected power supply capacity change.
Recommended Action Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc. Enter 'show environment power' and 'the show platform
internal command rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-2-PS_CAPACITY_DIFFER: Detected power supplies with differing
capacity. It is recommended to have same capacity for both powersupplies otherwise
it may cause service disruptions
Explanation Detected a power supply that has differing capacity than the other power supply.
Recommended Action Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc. Enter 'show environment power' and 'the show platform
internal command rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-2-PS_DETECT: Power supply [dec] detected but shutdown
(Serial number [chars])
Explanation Power Supply is detected but shutdown.
Recommended Action Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-2-PS_FAIL: Power supply [dec] failed or shut down (Serial
number [chars])
Explanation Power Supply has failed or has been shutdown.
Recommended Action Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information. Refer to power supply document
on increasing decreasing power supply capacity, configuring power supplies, etc.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals