Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message PLATFORM-2-PS_FAIL: Power supply [dec] failed or shutdown (Serial
number [chars])
Explanation Power Supply has failed or has been shutdown.
Recommended Action Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information. Refer to power supply document
on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PLATFORM-2-PS_FANFAIL: Fan in Power supply [dec] failed
Explanation Fan module in the Power Supply has failed.
Recommended Action Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-2-PS_FANOK: Fan in Power supply [dec] ok
Explanation Fan module in the Power Supply is ok.
Recommended Action No action is required.
Error Message PLATFORM-2-PS_MISMATCH: Detected power supply [chars]. This reduces
the redundant power available to the system and can cause service disruptions
(Serial number [chars])
Explanation Detected a new power supply that has reduced capacity than an existing power supply.
Recommended Action Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc. Enter 'show environment power' and 'the show platform
internal command rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-2-PS_OK: Power supply [dec] ok (Serial number [chars])
Explanation Power Supply is ok.
Recommended Action No action is required.
Error Message PLATFORM-2-PS_RED_MODE_CHG: Power supply redundancy mode changed to
[chars]
Explanation Power supply redundancy mode changed notification.
Recommended Action Enter a 'show environment power' and 'the show platform internal command
rmationcommandrmationcommand' to collect more information.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals