2-489
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message PLATFORM-2-PS_REMOVE: Power supply [dec] removed (Serial number
[chars])
Explanation Power Supply is removed.
Recommended Action No action is required.
Error Message PLATFORM-2-PS_REMOVE_LAST: Unexpected removal of last power supply
[dec]. (Serial number [chars])
Explanation Unexpected removal of the only power supply in the system.
Recommended Action Power supply unit may be faulty. Contact the Cisco Technical Assistance
Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PLATFORM-2-PS_UNKNOWN: Detected an unknown power supply [dec] for
CISCO Multilayer Switch (Serial number [chars])
Explanation The system is unable to determine power supply type. Default power supply types will
be assumed.
Recommended Action Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc.
Error Message PLATFORM-2-PS_UNSUPPORTED: Detected an unsupported power supply [dec]
[chars] for CISCO Multilayer Switch (Serial number [chars])
Explanation This power supply is not supported for the Cisco Multilayer Switches.
Recommended Action Refer to power supply document on increasing decreasing power supply
capacity, configuring power supplies, etc.
Error Message PLATFORM-2-SYS_IDPROMBAD: Chassis IDPROM [dec] data invalid
Explanation Chassis IDPROM [decimal digit] contains invalid data.
Recommended Action Enter a 'show sprom module [decimal digit] 1' to read module IDPROM
contents and collect more information.
Error Message PLATFORM-2-SYS_IDPROMBAD_RECOVER_FAIL: Chassis IDPROM [dec] data
re-initialization Un-successful. Data is invalid
Explanation Chassis IDPROM [decimal digit] re-initialization was unsuccessful. Data is invalid.
Recommended Action Enter a 'show sprom module [decimal digit] 1' to read module IDPROM
contents and collect more information.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals