Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
Error Message PLATFORM-2-SYS_IDPROMBAD_RECOVER_PASS: Chassis IDPROM [dec] data
re-initialized successfully
Explanation Chassis IDPROM [decimal digit] invalid data was succesfully re-initialized to valid.
Recommended Action Enter a 'show sprom module [decimal digit] 1' to read module IDPROM
contents and verify the information.
Error Message PLATFORM-2-XBAR_DETECT: Xbar [dec] detected (Serial number [chars])
Explanation A new xbar in slot [decimal digit] is detected.
Recommended Action No action is required.
Error Message PLATFORM-2-XBAR_PWRFAIL_EJECTORS_OPEN: Both ejectors open, Xbar [dec]
will not be powered up (Serial number [chars])
Explanation The xbar cannot be powered up because both ejectors are open.
Recommended Action Enter a 'show platform internal all module [decimal digit]' and 'show module
internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents
to collect more information.
Error Message PLATFORM-2-XBAR_REMOVE: Xbar [dec] removed (Serial number [chars])
Explanation The xbar in slot [decimal digit] has been removed.
Recommended Action No action is required.
PLATFORM-3
Error Message PLATFORM-3-EJECTOR_STAT_CHANGED: Ejectors' status in slot [dec] has
changed, [chars] Ejector is [chars], [chars] Ejector is [chars]
Explanation Ejector status has changed.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message PLATFORM-3-MOD_BRINGUP_MULTI_LIMIT: Giving up after multiple attempts
were made to bring up the Module [dec], (Serial number [chars])
Explanation The module cannot be powered up even after three attempts.
Recommended Action Enter a 'show platform internal all module [decimal digit]' and 'show module
internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents
to collect more information.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals