2-509
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PORT Messages
Error Message PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_INVALID_TX_BBCREDIT: Interface
[chars] is down (Isolation due to ELP failure: loopback detected)
Explanation ELP failed on the interface due to loopback connection detected.
Recommended Action Connect to a port on another switch and try again.
Error Message PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_LOOPBACK_DETECTED: Interface
[chars] is down (Isolation due to ELP failure: invalid transmit B2B credit)
Explanation ELP failed on the interface due to invalid transmit B2B credit.
Recommended Action Configure the attached switchport correctly and try again.
Error Message PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_RATOV_EDTOV_MISMATCH: Interface
[chars] is down (Isolation due to ELP failure: R_A_TOV or E_D_TOV mismatch)
Explanation ELP failed on the interface due to R_A_TOV or E_D_TOV mismatch.
Recommended Action Configure R_A_TOV and E_D_TOV values correctly and try again.
Error Message PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_REVISION_MISMATCH: Interface
[chars] is down (Isolation due to ELP failure: revision mismatch)
Explanation ELP failed on the interface due to revision mismatch.
Recommended Action Configure the attached switchport correctly and try again.
Error Message PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_UNKNOWN_FLOW_CTL_CODE:
Interface [chars] is down (Isolation due to ELP failure: invalid flow control code)
Explanation ELP failed on the interface due to invalid flow control code.
Recommended Action Configure the attached switchport correctly and try again.
Error Message PORT-5-IF_DOWN_ELP_FAILURE_ISOLATION_UNKNOWN_FLOW_CTL_PARAM:
Interface [chars] is down (Isolation due to ELP failure: invalid flow control
param)
Explanation ELP failed on the interface due to invalid flow control param.
Recommended Action Configure the attached switchport correctly and try again.
Error Message PORT-5-IF_DOWN_EPP_FAILURE: Interface [chars] is down (Error Disabled
- EPP Failure)
Explanation Trunk protocol failed.
Recommended Action 'show port internal event-history msgs' will indicate the trunk protocol
exchanges to determine why it failed.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals