PORT Messages
Error Message PORT-5-IF_DOWN_SRC_PORT_REMOVED: Interface [chars] is down(Tunnel src
port removed)
Explanation Tunnel source port of this FCIP interface has been removed.
Recommended Action The src interface with ip address that matches the ip address of the bound
entity is removed. This happens normally due to the module on which the src interface exists is
removed.
Error Message PORT-5-IF_DOWN_SUSPENDED: Interface [chars] is down (Suspended)
Explanation This interface belongs to a port channel and has been suspended to an error while
bringing it up.
Recommended Action In most cases, you can recover using the following commands 'config
terminal', 'interface [char]', 'shutdown', 'no shutdown' on the interface. If this happens again obtain
output of 'show port internal all interface [char]' on the interface.
Error Message PORT-5-IF_DOWN_SUSPENDED_BY_MODE: Interface [chars] is down
(Suspended due to incompatible mode)
Explanation This interface belongs to a port channel and operational mode of the interface is
different from that of the port channel.
Recommended Action Change the mode and the trunking mode of the port channel from 'auto' and
check to ensure that the remote end of the interface also belongs to the same port channel.
Error Message PORT-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface [chars] is down
(Suspended due to incompatible speed)
Explanation This interface belongs to a port channel and operational speed of the interface is
different from that of the port channel.
Recommended Action Change the speed of the port channel from 'auto' and check to ensure that the
remote end of the interface also belongs to the same port channel.
Error Message PORT-5-IF_DOWN_SUSPENDED_BY_WWN: Interface [chars] is down (Suspended
due to incompatible remote switch WWN)
Explanation This interface belongs to a port channel and remote switch WWN of the interface is
different from that of the port channel.
Recommended Action Ensure that this interface is connected to the same remote switch as all the
other interfaces in the port channel.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals