2-644
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_EXECVE_FAILED
) Internal error - program launch [chars]
Explanation The process was unable to launch the IO program. Node was rebooted due to this error.
Recommended Action If this error is repeated continously, 1. Re-install the code on the node. The
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_FORK_FAILED )
Internal error - fork failed [chars]
Explanation The process was unable to launch the IO program. Node was rebooted due to this error.
Recommended Action If this error is repeated continously, 1. Re-install the code on the node. The
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_INTERNAL_EXIT_LOGIC_ERR ) Internal error - bad exit code [chars]
Explanation Node was warmstarted due to internal logic error.
Recommended Action 1. Ensure that the software is at the latest level on the cluster. 2. Contact the
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_INTERNAL_UNKNOWN_EXEC_MODE ) Internal error - run mode [chars]
Explanation Node was rebooted due to internal logic error.
Recommended Action 1. Ensure that the software is at the latest level on the cluster. 2. Contact the
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_IOP_EXITED_DUE_TO_SIGNAL ) Internal error - signal caused exit
[chars]
Explanation The IO process exited because of a signal which was not caught. Node was warmstarted
due to this error.
Recommended Action 1. Ensure that the software is at the latest level on the cluster. 2. Contact the
Cisco Technical Assistance Center (TAC) through the Cisco Support web site
http://www.cisco.com/tac.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals