Configuration - I/O Boards
9-133
9
iControl DC
Rear Hall Door Stop Button: Input from a rear hall door stop button (active low).
Rear Main Door Close Button: Input from the rear main door close button.
Rear Main Door Hold Button: Input from the rear main door hold button.
Rear Main Door Open Button: Input from the rear main door open button.
Rear Main Door Stop Button: Input from the rear main door stop button (active low).
Rear Momentary Pressure Close: Activation overrides rear door close software setting.
Rear Momentary Pressure Open: Activation overrides rear door open software setting.
Rear Photo Eye Cut Out: Input from the rear key switch that disables rear door photo
eye operation.
Car Calls - Front Main COP:
Car Call - Front Main COP button, Floor 1 —96: Inputs from front car call buttons for
non-serial, main car operating panel.
Sequential Step Scan Up Front Main COP: Sequential step scan car calls option input.
Sequential Step Scan Down Front Main COP: Sequential step scan car calls option
input.
Disable Front Main COP: Input used to disable the front car call and door buttons of
the main Car Operating Panel.
Car Calls - Rear Main COP
Car Call - Rear Main COP button, Floor 1 —96: Inputs from rear car call buttons for
non-serial, main car operating panel.
Sequential Step Scan Up Rear Main COP: Sequential step scan car calls option input.
Sequential Step Scan Down Rear Main COP: Sequential step scan car calls option
input.
Disable Rear Main COP: Input used to disable the rear car call and door buttons of the
main Car Operating Panel.
Car Calls - Front Aux COP
Car Call - Front Aux COP button, Floor 1 —96: Inputs from front car call buttons for
non-serial, auxiliary car operating panel.
Sequential Step Scan Up Front Aux COP: Sequential step scan car calls option input.
Sequential Step Scan Down Front Aux COP: Sequential step scan car calls option
input.
Disable Front Aux COP: Input used to disable the front car call and door buttons of the
auxiliary Car Operating Panel.
Car Calls - Rear Aux COP
Car Call - Rear Aux COP button, Floor 1 —96: Inputs from rear car call buttons for
non-serial, auxiliary car operating panel.
Sequential Step Scan Up Rear Aux COP: Sequential step scan car calls option input.
Sequential Step Scan Down Rear Aux COP: Sequential step scan car calls option input.
Disable Rear Aux COP: Input used to disable the rear car call and door buttons of the
auxiliary Car Operating Panel.