2 Parameters
2.1 Overview of parameters
SINAMICS DCP
16 List Manual (LH21), 05/2016
BICO: Full parameter name / abbreviated name
The following abbreviations can appear in front of the parameter name:
Drive object (function module)
A drive object (DO) is an independent, "self-contained" functional unit that has its own
parameters and, in some cases, faults and alarms.
A parameter can belong to one, several, or all drive objects.
The following information relating to "Drive object" and "Function module" can be displayed
under the parameter number:
• BI: Binector Input
This parameter is used for selecting the source of a digital signal.
• BO: Binector Output
This parameter is available as a digital signal for interconnection with other
parameters.
• CI: Connector Input
This parameter is used for selecting the source of an “analog” signal.
• CO: Connector Output
This parameter is available as an “analog” signal for interconnection with other
parameters.
• CO/BO: Connector/Binector Output
This parameter is available as an "analog" and digital signal for interconnection
with other parameters.
Note
A connector input (CI) cannot be just interconnected with any connector output (CO, signal
source).
When interconnecting a connector input using the commissioning software, only the
corresponding possible signal sources are listed.
Table 2-1 Data in the "Drive object (function module)" field
Drive object (function
module)
Type Meaning
All objects - This parameter is used by all drive objects.
CU_DCP 6 Advanced Control Unit SINAMICS DCM (CUD)
CU_DCP (PROFINET) - Advanced Control Unit SINAMICS DCP (CUD) with "PROFINET" function module
(p0108.31).
DCP_CTRL 17 Closed-loop control for SINAMICS DCP.
DCP_CTRL (PROFINET) - Closed-loop control for SINAMICS DCP with "PROFINET" function module
(r0108.31).
TM150 208 Terminal Module 150.
TM15DI_DO 204 Terminal Module 15 (for SINAMICS).
TM31 200 Terminal Module 31.