Plate and strip-tube layout
You can print a plate layout in the Plate Manager software. See “Print the plate layout” on page 125.
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
11
12
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
1
2
3
4
5
6
8
7
2
1
Figure 9 96-well plate and strip-tube capillary-to-plate
mapping (8 capillar
y)
Injection 1, 3, 5, 7, 9, 11 (wells A–H)
Injection 2, 4, 6, 8, 10, 12 (wells A–H)
2 3 4
1
4
7
10
13
16
19
22
2
5
8
11
14
17
20
23
3
6
9
12
15
18
21
24
1
4
7
10
13
16
19
22
2
5
8
11
14
17
20
23
3
6
9
12
15
18
21
24
1
4
7
10
13
16
19
22
2
5
8
11
14
17
20
23
3
6
9
12
15
18
21
24
1
4
7
10
13
16
19
22
2
5
8
11
14
17
20
23
3
6
9
12
15
18
21
24
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
11
12
1
Figure 10 96-well plate and strip-tube capillary-to-
plat
e mapping (24 capillary)
Injection 1 (wells A1–H3)
Injection 2 (wells A4–H6)
Injection 3 (wells A7–H9)
Injection 4 (wells A10–H12)
1
1
4
4
7
7
10
10
13
13
16
16
19
19
22
22
1
1
4
4
7
7
10
10
13
13
16
16
19
19
22
22
2
2
5
5
8
8
11
11
14
14
17
17
20
20
23
23
2
2
5
5
8
8
11
11
14
14
17
17
20
20
23
23
3
3
6
6
9
9
12
12
15
15
18
18
21
21
24
24
3
3
6
6
9
9
12
12
15
15
18
18
21
21
24
24
1
1
4
4
7
7
10
10
13
13
16
16
19
19
22
22
1
1
4
4
7
7
10
10
13
13
16
16
19
19
22
22
2
2
5
5
8
8
11
11
14
14
17
17
20
20
23
23
2
2
5
5
8
8
11
11
14
14
17
17
20
20
23
23
3
3
6
6
9
9
12
12
15
15
18
18
21
21
24
24
3
3
6
6
9
9
12
12
15
15
18
18
21
21
24
24
1
1
4
4
7
7
10
10
13
13
16
16
19
19
22
22
1
1
4
4
7
7
10
10
13
13
16
16
19
19
22
22
2
2
5
5
8
8
11
11
14
14
17
17
20
20
23
23
2
2
5
5
8
8
11
11
14
14
17
17
20
20
23
23
3
3
6
6
9
9
12
12
15
15
18
18
21
21
24
24
3
3
6
6
9
9
12
12
15
15
18
18
21
21
24
24
3
3
6
6
9
12
12
15
15
18
18
21
21
24
24
10
13
13
16
16
19
19
22
22
10
13
13
16
16
19
19
22
22
11
14
14
17
17
20
20
23
23
11
14
14
17
17
20
20
23
23
12
15
15
18
18
21
21
24
24
1
1
4
4
7
7
10
1
1
4
4
7
7
10
2
2
5
5
8
8
11
2
2
5
5
8
8
11
3
3
6
6
9
9
12
10
13
16
19
22
11
14
17
20
23
12
15
18
21
24
1
4
7
2
5
8
3
6
9
1
4
7
10
2
5
8
11
3
6
9
12
13
16
19
22
14
17
20
23
12
15
18
21
24
12
12
12
12
1
2
9
3
6
12
15
18
21
24
13
16
19
22
14
17
20
23
1
4
7
10
2
5
8
11
12
12
12
12
12
12
12
12
9
3
3
6
9
12
15
18
21
24
10
13
16
19
22
11
14
17
20
23
1
4
7
2
5
8
12
12
12
12
12
12
12
12
4
9
Figure 11 384-well plate capillary-to-plate mapping (24 capillary only)
Injection 1 (wells A1, A3, A5; wells C1, C3, C5; wells E1, E3, E5; wells G1, G3, G5; wells I1, I3, I5; wells K1, K3, K5;
wells M1, M3, M5; wells O1, O3, O5)
Injection 2 (wells B1, B3, B5; wells D1, D3, D5; wells F1, F3, F5; wells H1, H3, H5; wells J1, J3, J5; wells L1, L3, L5;
wells N1, N3, N5; wells P1, P3, P5)
Injection 3 (wells A2, A4, A6; wells C2, C4, C6; wells E2, E4, E6; wells G2, G4, G6; wells I2, I4, I6; wells K2, K4, K6;
wells M2, M4, M6; wells O2, O4, O6)
Injection 4 (wells B2, B4, B6; wells D2, D4, D6; wells F2, F4, F6; wells H2, H4, H6; wells J2, J4, J6; wells L2, L4, L6;
wells N2, N4, N6; wells P2, P4, P6)
Chapter 3 Prepare the samples
Plate and strip-tube layout
3
SeqStudio
Flex Series Genetic Analyzer with Instrument Software v1.0 User Guide
75