Pre-run check messages and plate alerts during a run
Pre-run checks are performed at the following times during a run:
When a plate run starts
When a re-injection is added to the Run queue
Before each injection
When a paused run is resumed
When a cancelled injection is added back to the Run queue
A partial list of pre-run checks is shown below.
Checks for valid spatial and spectral calibrations.
Checks for a passing install run.
Checks consumables expiration, volume, and number of remaining injections.
Determines if adequate storage space is available for results.
Determines if the plate has been installed in the drawer for more than 24 hours.
Checks that the save locations specified in the plate file are available and writable.
If you run using the automated barcode workflow, performs additional checks. See “Run plates
with the automated barcode workflow” on page 147.
Pre-run checks when a plate run starts or a re-injection or a cancelled
injection is added to the Run queue
Pre-run checks are performed when a plate run starts or when a re-injection or a cancelled injection
is added to the Run queue. If these pre-run checks do not pass, a message screen is displayed. Two
message types are possible:
Pre-run check failure message—The error condition must be corrected before the run can start.
Pre-run check warning message—For information only, tap OK to start the run.
Examples of pre-run check failure messages include "No spatial calibration available for capillary
array", "Plate type of the installed plate does not match the plate file".
Examples of pre-run check warning messages include "Injections on plate will exceed or have
exceeded 24 hours on instrument", "Network drive save location is not writable".
Pre-run checks before each injection or when a paused run is resumed
Pre-run checks are also performed before each injection or when a paused run is resumed. If these
pre-run checks do not pass, a
!
(Plate alert) symbol is displayed at the top of a plate position.
To display the reason for the alert, tap the
!
(Plate alert) symbol. The Notifications screen is
displayed. For more information, see the following sections:
“View alert and notification details” on page 149
“Plate alert troubleshooting” on page 507
Chapter 6 Start and monitor a run
Pre-run check messages and plate alerts during a run
6
146
SeqStudio
Flex Series Genetic Analyzer with Instrument Software v1.0 User Guide

Table of Contents

Related product manuals