* The range value is ten times the time per division.
*/
viPrintf(vi, ":TIM:RANG 2e-3\n");
/* TIME_REFERENCE - Possible values are LEFT and CENTER:
* - LEFT sets the display reference one time division from the
* left.
* - CENTER sets the display reference to the center of the screen.
*/
viPrintf(vi, ":TIMEBASE:REFERENCE CENTER\n");
/* TRIGGER_SOURCE - Selects the channel that actually produces the
* TV trigger. Any channel can be selected.
*/
viPrintf(vi, ":TRIGGER:TV:SOURCE CHANNEL1\n");
/* TRIGGER_MODE - Set the trigger mode to, EDGE, GLITch, PATTern,
* CAN, DURation, IIC, LIN, SEQuence, SPI, TV, or USB.
*/
viPrintf(vi, ":TRIGGER:MODE EDGE\n");
/* TRIGGER_EDGE_SLOPE - Set the slope of the edge for the trigger
* to either POSITIVE or NEGATIVE.
*/
viPrintf(vi, ":TRIGGER:EDGE:SLOPE POSITIVE\n");
}
/*
* extra
* ------------------------------------------------------------------
* The commands in this function are not executed and are shown for
* reference purposes only. To execute these commands, call this
* function from main.
*/
void extra (void)
{
/* RUN_STOP (not executed in this example):
* - RUN starts the acquisition of data for the active waveform
* display.
* - STOP stops the data acquisition and turns off AUTOSTORE.
*/
viPrintf(vi, ":RUN\n");
viPrintf(vi, ":STOP\n");
/* VIEW_BLANK (not executed in this example):
* - VIEW turns on (starts displaying) an active channel or pixel
* memory.
* - BLANK turns off (stops displaying) a specified channel or
* pixel memory.
*/
viPrintf(vi, ":BLANK CHANNEL1\n");
viPrintf(vi, ":VIEW CHANNEL1\n");
/* TIME_MODE (not executed in this example) - Set the time base
* mode to MAIN, DELAYED, XY or ROLL.
*/

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 5000 Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 5000 Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 5000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals