Programming Examples 12
Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide 725
Console.WriteLine("Preamble XREFerence: {0:e}", fXreference);
double fYincrement = fResultsArray[7];
Console.WriteLine("Preamble YINCrement: {0:e}", fYincrement);
double fYorigin = fResultsArray[8];
Console.WriteLine("Preamble YORigin: {0:e}", fYorigin);
double fYreference = fResultsArray[9];
Console.WriteLine("Preamble YREFerence: {0:e}", fYreference);
/* QUERY_WAVE_DATA - Outputs waveform records to the controller
* over the interface that is stored in a buffer previously
* specified with the ":WAVeform:SOURce" command.
*/
/* READ_WAVE_DATA - The wave data consists of two parts: the
* header, and the actual waveform data followed by a
* New Line (NL) character. The query data has the following
* format:
*
* <header><waveform data block><NL>
*
* Where:
*
* <header> = #800002048 (this is an example header)
*
* The "#8" may be stripped off of the header and the remaining
* numbers are the size, in bytes, of the waveform data block.
* The size can vary depending on the number of points acquired
* for the waveform which can be set using the
* ":WAVEFORM:POINTS" command. You may then read that number
* of bytes from the oscilloscope; then, read the following NL
* character to terminate the query.
*/
// Read waveform data.
nLength = oscp.DoQueryIEEEBlock(":WAVeform:DATA?",
out ResultsArray);
Console.WriteLine("Read waveform data ({0} bytes).", nLength);
// Make some calculations from the preamble data.
double fVdiv = 32 * fYincrement;
double fOffset = fYorigin;
double fSdiv = fPoints * fXincrement / 10;
double fDelay = (fPoints / 2) * fXincrement + fXorigin;
// Print them out...
Console.WriteLine("Scope Settings for Channel 1:");
Console.WriteLine("Volts per Division = {0:f}", fVdiv);
Console.WriteLine("Offset = {0:f}", fOffset);
Console.WriteLine("Seconds per Division = {0:e}", fSdiv);
Console.WriteLine("Delay = {0:e}", fDelay);
// Print the waveform voltage at selected points:
for(inti=0;i<1000;i=i+50)
Console.WriteLine("Data point {0:d} = {1:f2} Volts at "

Table of Contents

Other manuals for Agilent Technologies InfiniiVision 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies InfiniiVision 5000 Series and is the answer not in the manual?

Agilent Technologies InfiniiVision 5000 Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelInfiniiVision 5000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals