2-641
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_NO_FABRIC ) The node
is unable to see the FC fabric [chars]
Explanation No active/functioning logical FC port was detected by the software.
Recommended Action Reload the node. If the problem persists, replace the Caching Services Module.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_PWR_DMN_ERR ) Power
domain error [chars]
Explanation The two nodes in an IO group are on the same Caching Services Module.
Recommended Action Determine if both nodes on the Caching Services Module are in fact in the
same IO group. If so, determine what the configuration should be. Remove one of the nodes and add
a node to the IO group which is not on the same Caching Services Module. If not, ask IBM Product
Support for assistance.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_REPEATED_ASSERTS )
Node repeatedly crashing due to a software fault [chars]
Explanation The number of software faults has exceeded the maximum allowed for the time period.
Recommended Action 1. Delete the node from the cluster. 2. Try to add the node back into the cluster.
3. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster with the
latest level of code. 4. If the error continues, ask IBM Product Support for assistance.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_NODERR_RESET_AND_REJECT )
Node data not found - node rejected from cluster [chars]
Explanation Node data was not found. The node has been rejected from the from cluster.
Recommended Action Examine error logs to determine if another recorded error caused the loss of
the node data and, if so, follow the actions for that error. If no other error was recorded, the node
may have lost power without saving data or been reset. Attempt to determine the cause of the power
loss or reset. If no cause can be determined, then: 1. Re-install the code on the node. The node will
have to be removed and re-added back to the cluster. 2. Ensure that the software is at the latest level
on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest level of code.
3. If the error continues, ask IBM Product Support for assistance. It may be necessary to replace the
Caching Services Module.
Error Message SVC-3-NODE_ERR_MSG: [chars]
Explanation Syslog message from a SVC interface node.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals