Page #684 background imageLoading...
Page #684 background image
Send document comments to nexus7k-feedback-doc@cisco.com
2-646
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_WAITPID_FAILED
) Internal error - waitpid failed [chars]
Explanation The process was unable to launch the IO program properly. Node was warmstarted due
to this error.
Recommended Action If this error is repeated continously, 1. Reload the node. 2. If the error persists,
re-install the code on the node. The node will then have to be removed and re-added back to the
cluster. 3. Ensure that the software is at the latest level on the cluster. If not, upgrade the cluster and
if necessary repeat step 2 with the latest level of code. 4. If the error continues, ask IBM Product
Support for assistance.
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_WARMSTART_MEMORY_FAILED ) Internal error - warmstart memory device
[chars]
Explanation The process was unable to warmstart the memory device. \ Node was rebooted due to
this error.
Recommended Action If this error is repeated continously, 1. Re-install the code on the node. The
node will then have to be removed and re-added back to the cluster. 2. Ensure that the software is at
the latest level on the cluster. If not, upgrade the cluster and if necessary repeat step 1 with the latest
level of code. 3. If the error continues, ask IBM Product Support for assistance.
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec]
SS_EID_FC_ER_MAPPING_STOPPED ) FlashCopy has been stopped [chars]
Explanation A Flash Copy mapping task has been stopped because of an error. \ A stopped flash
copy may affect the status of other VDisks in the same I/O group. Preparing the stopped flash copies
as soon as possible is advised.
Recommended Action 1. Correct higher priority errors. Then, prepare and start the Flash Copy task
again. 2. Mark the error you have just repaired as fixed.
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_FC_ER_PREPARE_FAILED
) FlashCopy prepare failed due to cache flush failure [chars]
Explanation A Flash Copy prepare task has failed because a cache flush has failed.
Recommended Action 1. Correct higher priority errors, then retry the prepare tasks. 2. Mark the error
you have just repaired as fixed.
Error Message SVC-4-NODE_WARNING_MSG: (SVC [dec]/[dec] SS_EID_FC_ER_STOP_COMPLETED
) Flash Copy Stopped [chars]
Explanation The Flash Copy mapping or consistency group has entered the STOPPED state as a
result of a user request to stop.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?