142 General Service and Replacing FRUs
Required Tools
Installing, adding, removing, and replacing customer replaceable units (CRUs) and field replaceable units
(FRUs) for the Dell PowerVault ML6000 tape library may require the following tools:
• Flathead screwdriver
• Phillips #2 screwdriver
• T10 TORX screwdriver with a static safe handle
General Service Guidelines
I/O Fan Blades On/Normal
I/E Station Lock Assembly Power off
I/E Station Slide Assembly Power off
I/E Station Safety Doors Power off
Operator Panel (LCD Front Panel
Display)
Power off
Picker Assembly Power off
Y-Carriage Assembly Power off
Y-Motor Power off
Cable Spool Power off
ALL LIBRARIES TALLER THAN 14U MUST BE INSTALLED IN A RACK
HAVING A MAIN PROTECTIVE EARTHING (GROUNDING) TERMINAL,
AND POWER MUST BE SUPPLIED VIA AN INDUSTRIAL PLUG AND
SOCKET-OUTLET AND/OR AN APPLIANCE COUPLER COMPLYING
WITH IEC 60309 (OR AN EQUIVALENT NATIONAL STANDARD) AND
HAVING A PROTECTIVE EARTH (GROUND) CONDUCTOR WITH A
CROSS SECTIONAL AREA OF AT LEAST 1.5 MM
2
(14 AWG).
TO ENSURE PROPER AIRFLOW AND ACCESS SPACE, ALLOW 60 CM
(24 INCHES) IN THE FRONT AND BACK OF THE LIBRARY.
UNDER NO CIRCUMSTANCES SHOULD A RACK BE MOVED WHILE
LOADED WITH ONE OR MORE MODULES.
Table 9 Library Components: Required Library State (Continued)
Part Required Library Status