PowerVault ML6000 Maintenance Guide 7
You can use the Service menu to access various tests for the library’s tape drives or for the entire library,
to ensure that the library is functioning as expected.
The following tests are available:
• Drives > Drive Tests
• Wrap Test—Performs a test to ensure that the tape drive circuitry is working by testing the
external tape drive interface circuitry.
• Reset—Power cycles the tape drive while the tape drive remains in the drive sled in the library.
• Drives > Media Tests
• Fast R/W Test—Reads and writes two wraps worth of data in each of the tape’s four data
sections. For this test, insert a scratch data cartridge in the top I/E station slot. During the test,
the drive overwrites the data on the cartridge.
Table 1 Service Menu vs. Web Client Diagnostics Menu
Service Menu Web Client Diagnostics Menu
Tools
> EKM Path Diagnostics
Drives
> Drive Tests
> Wrap Test
> Reset
> Media Tests
> Fast R/W Test
> Media Test
> Read/Write Test
> Self Test
System
> Library Tests
> Robotics
> I/E
> Barcode
> Door
> Sensors
EKM
> EKM Path Diagnostics
Driv
es
> Drive Tests
> Drive Reset
> Media Tests
> Drive Self Test
> Read/Write Test
> Fast Read/Write Test
> Media Test
R
obotics
> Robotics Get/Put Test
There are different types of wrap tools for SCSI, Fibre Channel, and SAS
tape drives. You must install the appropriate wrap tool for the tape drive
type when executing this test. Performing this test without a wrap tool
installed will cause the test to fail.