EasyManuals Logo

Dell PowerVault ML6000 Maintenance Guide

Dell PowerVault ML6000
494 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #352 background imageLoading...
Page #352 background image
334 Troubleshooting the Tape Library
T135
T135 - Tape Drive Type Change
Description GUI Description: An assigned tape drive has been replaced with a tape drive
of a different type.
Explanation: A tape drive that is assigned to a partition has been replaced
with a tape drive of a different type, where type is defined by the tape drive's
vendor, generation, and interface. This RAS ticket is generated to notify the
user of the tape drive type change.
Detection Scenarios Installation of a tape drive into a library drive slot triggers the library to
discover it.
Bootup causes the library to physically discover any tape drive that is
electrically connected in the system.
Root Causes End user replaced an assigned tape drive with a tape drive of a different
generation, interface, or vendor.
Service Resolution
Steps
Perform DR101 - Resolve Tape Drive Type Change
on page 411.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1Drive Sled

Table of Contents

Other manuals for Dell PowerVault ML6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault ML6000 and is the answer not in the manual?

Dell PowerVault ML6000 Specifications

General IconGeneral
BrandDell
ModelPowerVault ML6000
CategoryStorage
LanguageEnglish

Related product manuals