306 Troubleshooting the Tape Library
T105
T105 - FC I/O Blade Temperature Alert
Description GUI Description: An FC I/O blade issued a temperature warning/alert.
Explanation: The FC I/O blade detected a temperature problem.
Detection Scenarios The FC I/O blade has an internal temperature sensor. This RAS ticket is
generated when it detects a temperature that is above specification.
Root Causes Fan blade is not working properly. The fan blade is also monitored. Check
for a fan blade ticket to isolate the problem.
External temperature of the library is not within specification.
Temperature sensor on the FC I/O blade is not working properly.
Service Resolution
Steps
Perform DR065 - Resolve FC I/O Blade Temperature Alert
on page 396.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1 FC I/O Blade
2Fan Blade

Table of Contents

Other manuals for Dell PowerVault ML6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault ML6000 and is the answer not in the manual?

Dell PowerVault ML6000 Specifications

General IconGeneral
BrandDell
ModelPowerVault ML6000
CategoryStorage
LanguageEnglish

Related product manuals