PowerVault ML6000 Maintenance Guide 215
T018
Status: Implemented in firmware version 580.
T018 - Invalid Drive Sled Connection
Description GUI Description: The library detected that a tape drive is incorrectly
connected to an FC I/O blade.
Explanation: The library detected that a library control path drive is
connected to an FC I/O blade. Such configuration is invalid and the tape
drives need to be disconnected from the FC I/O blade or reconfigured to not
enable a library control path.
Detection Scenarios The FC I/O blade reports that an SMC device was detected.
The library detected that an FC I/O blade reports connectivity to a tape drive
that is configured as a control path drive.
Root Causes User error when connecting the drive to the SAN.
User error regarding enabled drive features.
Resolution See: DR013 - Resolve Drive Connection Issue
on page 373.
Possible CRUs/FRUs None