328 Troubleshooting the Tape Library
T129
T129 - Drive Sled Firmware Image Error
Description GUI Description: Drive sled firmware cannot be auto-leveled, due to a
missing or corrupt drive sled firmware image.
Explanation: During an attempt to autolevel the drive sleds, the library
detected a missing or corrupt UDS.lif (drive sled firmware) file.
Detection Scenarios Main library firmware that controls and performs drive sled firmware updates
detects that the drive sled firmware update file is missing or corrupted.
Root Causes The drive sled firmware update file is missing or corrupted.
Service Resolution
Steps
Perform D
R095 - Resolve Drive Sled Auto-Level Failure on page 409.
Possible CRUs/FRUs None

Table of Contents