EasyManuals Logo

Dell PowerVault ML6000 Maintenance Guide

Dell PowerVault ML6000
494 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #265 background imageLoading...
Page #265 background image
PowerVault ML6000 Maintenance Guide 247
T050
T050 - Drive TapeAlert 31 – Hardware B
Description GUI Description: The tape drive detected an internal hardware problem.
Explanation: System determines that the tape drive has issued a
TapeAlert 31, indicating a hardware error that requires a tape drive power
cycle before the tape drive might recover to a usable state.
Detection Scenarios Tape drive issues a TapeAlert 31, which is recognized by the library during the
continuous 4-second polling cycle of tape drive status.
Root Causes Tape drive has determined that there is a problem per its internal algorithms.
Service Resolution
Steps
1 Perform DR049 -
Resolve Drive TapeAlert 30, 31 - Drive Hardware Error on
page 390.
2Use the Details option in the RAS ticket to identify which tape drive reported
the RAS ticket. If possible, check the front of the tape drive for error
indications.
3 Isolate the media which was used in the tape drive and caused the error.
4 Clear the RAS ticket.
5 Upgrade the tape drive to the latest drive firmware posted on http://
support.dell.com. If already at the latest firmware, power cycle the drive sled
by either reseating it, rebooting the unit, or performing an emergency reset
on the drive by holding the eject button down for 5 seconds.
6 Use a piece of known good media and retry the operation on the tape drive.
7 If using 400G library firmware or later, run the IVT - Drive test from the
Library Tests option accessed through the operator panel.
Note: IVT is optimized for library firmware versions 520G and above and
libraries built after July 1, 2008 (serial numbers with last four digits 8602 and
above).
If your library was built on or before July 1, 2008, and you are running
firmware version 520G or later, you will not be able to run the IVT test,
even though the selection is available.
If your library was built on or before July 1, 2008, and you are running
firmware version 500G or earlier, you can run the test, but it is not
recommended because it may produce erroneous results.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1Drive Sled

Table of Contents

Other manuals for Dell PowerVault ML6000