PowerVault ML6000 Maintenance Guide 349
T153
T153 - Drive Control Failure
Description GUI Description: A tape drive failed to configure a requested drive
functionality.
Explanation: The drive sled controller firmware commanded the drive to
configure a specific function, such as enabling or disabling library managed
encryption for the drive, but the drive failed to perform the requested
operation.
Detection Scenarios • Library control firmware received a drive sled event,
E_DDC_LME_ENABLED, indicating that the tape drive did enable library
managed encryption, but the library requested that the drive configure for
application managed encryption (AME).
• Library control firmware received a drive sled event,
E_DDC_LME_DISABLED, indicating that the tape drive did not enable for
library managed encryption, but the library requested that the drive configure
for LME.
• Library Control firmware received a drive sled response that indicates a drive
configuration request failed
Root Causes Drive sled or tape drive issue.
Service Resolution
Steps
Perform DR110 - Re
solve Drive Control Failure on page 414.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1Drive Sled