PowerVault ML6000 Maintenance Guide 313
T113
T113 - FC I/O Blade Voltage Alarm
Description GUI Description: An FC I/O blade issued a voltage alarm.
Explanation: The FC I/O blade has detected that 1 of its 5 monitored voltage
levels has spiked above, or dropped below, a safe threshold.
Detection Scenarios A sensor that monitors a voltage level on the FCB detects a voltage change
beyond tolerable limits.
Root Causes FCB hardware is not handling the voltage correctly.
A power supply is malfunctioning.
Service Resolution
Steps
Perform DR073 - Resolve FC I/O Blade Voltage Alarm
on page 399.
Note: If there are other active voltage/power-related tickets, the problem may
be caused by the power supply to the library, so you can dispatch a power
supply; otherwise, the only CRU/FRU you should dispatch is the
FC I/O blade.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1 FC I/O Blade
2 Power Supply (only dispatch if warranted; see note in Service Resolution
Steps above)