PowerVault ML6000 Maintenance Guide 311
T111
T111 - FCB Product Mismatch
Description GUI Description: An incompatible FC I/O blade installation has been
detected.
Explanation: During bootup, or when an FC I/O blade is inserted, the library
checks the product designation of the installed FC I/O blades. If an FC I/O
blade has been added to the library whose product designation does not
match the product type of the library, this ticket is generated.
Detection Scenarios When queried, the FC I/O blade returns a product designation that does not
match what is expected for the library.
Root Causes • User installed an FC I/O blade that is not compatible with the library.
• Firmware error on the LCB.
Service Resolution
Steps
Perform DR071 - Resolve FC I/O Blade Product Mismatch
on page 398.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1 FC I/O Blade