PowerVault ML6000 Maintenance Guide 195
T000
T000 - Tape Cartridge Stuck in Picker, Motion OK
Description GUI Description: The library detected an initialization problem.
Explanation: Library firmware detected that the System Interface Component
(SIC) is stuck in an initialization sequence and cannot continue. The library
may need to be rebooted or power-cycled to recover from the initialization
sequence issue that prevents the library from initializing.
Detection Scenarios A watchdog monitoring of the startup sequence determined the SIC hang
condition
Root Causes An unknown race condition during SIC initialization prevents proper startup
sequence.
Service Resolution
Steps
Perform DR098 - Resolve Hardware Clock Failure
on page 410.
Possible CRUs/FRUs None