Loading...
300 Troubleshooting the Tape Library
T099
T099 - Internal FC I/O Blade Memory Error
Description GUI Description: Memory Error Detected on Fibre Channel Blade.
Explanation: An error with the FC I/O blade’s internal memory has been
detected.
Detection Scenarios During start up, the FC I/O blade detected an error in its internal memory.
Root Causes FC I/O blade hardware error.
Service Resolution
Steps
Perform DR059 - Resolve FC I/O Blade Memory Error
on page 394.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1 FC I/O Blade

Table of Contents