T046
T046 - Drive TapeAlert 21 – Clean Periodic
Description GUI Description: The drive is requesting cleaning at the next convenient
opportunity.
Explanation: System determines that the tape drive has issued a
TapeAlert 21, indicating that the tape drive requires cleaning. This should be
coincident with a C on the tape drive’s seven-segment display.
Detection Scenarios Tape drive issues a TapeAlert 21, which is recognized by the library during the
continuous four-second polling cycle of tape drive status.
Root Causes Tape drive has determined that there is a problem per its internal algorithms.
Service Resolution
Steps
1 Perform D
R018 - Resolve Drive Cleaning Requirement on page 375.
2Use the Details option in the RAS ticket to identify which tape drive reported
the RAS ticket.
3 Clear the RAS ticket.
4 Either manually move a known good cleaning tape to the tape drive or
perform a cleaning operation in the tape backup software.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
No library CRU or FRU is involved. Rather, this is an indication that the tape
drive requires a cleaning tape to continue. Use a known good cleaning tape to
clean the tape drive.

Table of Contents

Other manuals for Dell PowerVault ML6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerVault ML6000 and is the answer not in the manual?

Dell PowerVault ML6000 Specifications

General IconGeneral
BrandDell
ModelPowerVault ML6000
CategoryStorage
LanguageEnglish

Related product manuals