PowerVault ML6000 Maintenance Guide 255
T059
T059 - Drive TapeAlert 53 - Tape System Area Read Failure
Description GUI Description: The tape drive issued a TapeAlert, indicating that a tape
system area read failed during a cartridge load operation.
Explanation: The library received a drive-generated TapeAlert 53, indicating
that a tape system area read failed during a load operation.
Detection Scenarios The tape drive generated and reported TapeAlert 53.
Root Causes The tape drive has determined and reported a problem per its internal error
analysis algorithms.
Service Resolution
Steps
1 Perform R
R008 - Remove and Replace Tape Cartridge on page 423.
Possible CRUs/FRUs None