EasyManua.ls Logo

Dell PowerVault ML6000 - T023

Dell PowerVault ML6000
494 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PowerVault ML6000 Maintenance Guide 221
T023
T023 - Drive Sled Fan Failure
Description GUI Description: The fan within the drive sled assembly is spinning too
slowly or does not rotate at all.
Detection Scenarios Regular polling/monitoring of the fan indicates a problem.
Root Causes Hardware failure of fan
Wiring or PCBA failure
Blocked air paths
Physical obstruction
Service Resolution
Steps
1 Perform RR001 - Remove and Replace Drive Sled
on page 420. See also
Removing and Replacing a Tape Drive
on page 129.
2Use the Details option in the RAS ticket to identify which tape drive is
generating the RAS ticket. If possible, check the front of the tape drive for
error indications. Check the suspect drive sled to determine if the fan is still
spinning. Check for any obstructions.
Possible CRUs/FRUs Note: Read and perform all resolution steps before dispatching any parts.
Dispatch the first part listed below for replacement. If this does not solve the
problem, dispatch the second part, and so on, in order. Dispatch only one part
(or set of parts) at a time.
1Drive Sled

Table of Contents

Other manuals for Dell PowerVault ML6000

Related product manuals