106 Library Installation and CRU Replacement
The library operator panel may display the following message; or it may blank out or change multiple
times during the firmware upgrade process.
23 When the firmware upgrade is complete, the login screen appears on the operator panel.
24 Enter the following default user name and password:
• User name: admin
•Password: password
25 Press OK.
The Setup Wizard screen appears.
26 Reconfigure your library settings as they were before.
Adding, Removing, and Replacing Power Supplies
The switch on the rear of each power supply shuts down power at the input of the individual power supplies.
The switch on the front of the 5U Library Control Module provides power to all 5U Library Control Module
and 9U Expansion Module power supplies.
Adding a Redundant Power Supply
These instructions explain how to add a second (redundant) power supply to a module. You may need to
add a redundant power supply to the library to make sure that the library does not go down (and become
inaccessible) if its original power supply happens to fail. The library automatically uses the redundant power
supply if the first power supply fails.
At this point the Scalar i500 Library is set up with factory default settings.
Contact Dell Support before restoring the configuration. In general, it is
recommended that you use the setup wizard to manually reconfigure the
library. It is not recommended to use the “restore configuration” tool to
restore the previous settings. Doing so will completely reinstall the former
library firmware level and potentially any defective configuration settings
encountered prior to installing the new LCB/compact flash card combo. If
you do restore a previous configuration and downrev firmware, you will
need to install the latest version of firmware again..
USING THE WEB CLIENT TO SHUT DOWN THE LIBRARY DOES NOT
TURN OFF LIBRARY POWER. LIBRARY POWER IS CONTROLLED AT
THE INDIVIDUAL POWER SUPPLIES AND AT THE FRONT PANEL OF
THE LIBRARY.
The 5U Library Control Module and each 9U Expansion Module with drives
must use at least one power supply. You can add a redundant power supply to
each module.
Installing one power supply in one module and another power supply in another
module does not provide redundant power; the two power supplies must reside
within the same module.