94 Library Installation and CRU Replacement
a. From the front of the library, find the Y-rail release mechanism, which is located on the left side
of the 5U Library Control Module. Squeeze the handle of the Y-rail release mechanism, lift it,
and release it so that it locks into place.
b. From the rear of the library, find the rear Y-rail release mechanism located in the interior of the
right side of the module. Squeeze the handle of the Y-rail release mechanism, lift it, and release
it so that it locks into place.
4 Remove the rack ears that fasten the module to the rack. See Using
the Rack-mount Kit to Install a
Library in a Rack on page 108 for detailed instructions on using the rack ears.
5 Loosen the thumbscrews located at the base of the front of the module.
1 Y-rail in locked, non-functional