EasyManuals Logo

NETGEAR ProSAFE M7100-24X User Manual

NETGEAR ProSAFE M7100-24X
776 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Using the Command-Line Interface
11
ProSafe M4100 Series Managed Switches
Common Parameter Values
Parameter values might be names (strings) or numbers. To use spaces as part of a name
parameter, enclose the name value in double quotes. For example, the expression “System
Name with Spaces” forces the system to accept the spaces. Empty strings (““) are not valid
user-defined strings. Table 2 describes common parameter values and value formatting.
Table 2. Parameter Descriptions
a (32 bits)
a.b (8.24 bits)
a.b.c (8.8.16 bits)
0xn (CLI assumes hexadecimal format)
0n (CLI assumes octal format with leading zeros)
{} curly braces
{choice1 |
choice2}
Indicates that you must select a parameter from the list of
choices.
| Vertical bars
choice1 | choice2
Separates the mutually exclusive choices.
[{}] Braces within
square brackets
[{choice1 |
choice2}]
Indicates a choice within an optional element.
Parameter Description
ipaddr This parameter is a valid IP address. You can enter the IP address in the following formats:
a.b.c.d (8.8.8.8)
In addition to these formats, the CLI accepts decimal, hexadecimal and octal formats
through the following input formats (where n is any valid hexadecimal, octal or decimal
number):
n (CLI assumes decimal format)
ipv6-address
FE80:0000:0000:0000:020F:24FF:FEBF:DBCB, or
FE80:0:0:0:20F:24FF:FEBF:DBCB, or
FE80::20F24FF:FEBF:DBCB, or
FE80:0:0:0:20F:24FF:128:141:49:32
For additional information, refer to RFC 3513.
Interface or
unit/slot/port
Valid slot and port number separated by forward slashes. For example, 0/1 represents slot
number 0 and port number 1.
Logical Interface Represents a logical slot and port number. This is applicable in the case of a port-channel
(LAG). You can use the logical unit/slot/port to configure the port-channel.
Character strings Use double quotation marks to identify character strings, for example, “System Name with
Spaces”. An empty string (“”) is not valid.
Table 1. Parameter Conventions
Symbol Example Description

Table of Contents

Other manuals for NETGEAR ProSAFE M7100-24X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSAFE M7100-24X and is the answer not in the manual?

NETGEAR ProSAFE M7100-24X Specifications

General IconGeneral
BrandNETGEAR
ModelProSAFE M7100-24X
CategorySwitch
LanguageEnglish

Related product manuals