EasyManua.ls Logo

NETGEAR ProSAFE M7100-24X - Sntp Client Port; Sntp Unicast Client Poll-Interval; Sntp Unicast Client Poll-Timeout

NETGEAR ProSAFE M7100-24X
776 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Utility Commands
551
ProSafe Managed Switch
no sntp client mode
This command disables Simple Network Time Protocol (SNTP) client mode.
Format no sntp client mode
Mode
sntp client port
This command sets the SNTP client port id to a value from 1-65535.
Default
Format sntp client port <portid>
Mode
no sntp client port
This command resets the SNTP client port back to its default value.
Format no sntp client port
Mode
sntp unicast client poll-interval
This command sets the poll interval for SNTP unicast clients in seconds as a power of two
where <poll-interval> can be a value from 6 to 10.
Default
Format sntp unicast client poll-interval <poll-interval>
Mode
no sntp unicast client poll-interval
This command resets the poll interval for SNTP unicast clients to its default value.
Format no sntp unicast client poll-interval
Mode
sntp unicast client poll-timeout
This command will set the poll timeout for SNTP unicast clients in seconds to a value from
1-30.
Global Config
123
Global Config
Global Config
6
Global Config
Global Config
Default
5

Table of Contents