IPv6 Commands
358
ProSafe Managed Switch
ipv6 mtu
This command sets the maximum transmission unit (MTU) size, in bytes, of IPv6 packets on
an interface. This command replaces the default or link MTU with a new MTU value.
Note:
The default MTU value for a tunnel interface is 1480. You cannot
change this value
.
no ipv6 mtu
This command resets maximum transmission unit value to default value.
Format no ipv6 mtu
Mode
ipv6 nd dad attempts
This command sets the number of duplicate address detection probes transmitted. Duplicate
address detection verifies that an IPv6 address on an interface is unique.
Default
Format ipv6 nd dad attempts <0 - 600>
Mode
no ipv6 nd dad attempts
This command resets to number of duplicate address detection value to default value.
Format no ipv6 nd dad attempts
Mode
Default
0 or link speed (MTU value (1500))
Format ipv6 mtu <1280-1500>
Mode
Interface Config
Interface Config
1
Interface Config
Interface Config

Table of Contents

Other manuals for NETGEAR ProSAFE M7100-24X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSAFE M7100-24X and is the answer not in the manual?

NETGEAR ProSAFE M7100-24X Specifications

General IconGeneral
BrandNETGEAR
ModelProSAFE M7100-24X
CategorySwitch
LanguageEnglish

Related product manuals