Switching Commands
203
ProSafe Managed Switch
isdp enable
This command enables ISDP on the interface.
Default
Format isdp enable
Mode
no isdp enable
This command disables ISDP on the interface.
Format no isdp enable
Mode
clear isdp counters
This command clears ISDP counters.
Format clear isdp counters
Mode
clear isdp table
This command clears entries in the ISDP table.
Format clear isdp table
Mode
show isdp
This command displays global ISDP settings.
Format show isdp
Mode
Enabled
Interface Config
Interface Config
Privileged EXEC
Privileged EXEC
Privileged EXEC
Term Definition
Timer
The frequency with which this device sends ISDP packets. This value is given in
seconds.
Hold Time
The length of time the receiving device should save information sent by this device. This
value is given in seconds.
Version 2
Advertisements
The setting for sending ISDPv2 packets. If disabled, version 1 packets are transmitted.