Switching Commands
81
ProSafe Managed Switch
no dot1x system-auth-control
This command is used to disable the dot1x authentication support on the switch.
Format no dot1x system-auth-control
Mode
dot1x timeout
This command sets the value, in seconds, of the timer used by the authenticator state
machine on this port. Depending on the token used and the value (in seconds) passed,
various timeout configurable parameters are set. The following tokens are supported:
guest-vlan-period
reauth-period
quiet-period
tx-period
supp-timeout
server-timeout
Default
• guest-vlan-period: 90 seconds
• reauth-period: 3600 seconds
• quiet-period: 60 seconds
• tx-period: 30 seconds
• supp-timeout: 30 seconds
• server-timeout: 30 seconds
Format dot1x timeout {{guest-vlan-period <seconds>} |{reauth-period
<seconds>} | {quiet-period <seconds>} | {tx-period <seconds>} |
{supp-timeout <seconds>} | {server-timeout <seconds>}}
Mode
Global Config
Tokens Definition
The time, in seconds, for which the authenticator waits to see if any EAPOL packets are
received on a port before authorizing the port and placing the port in the guest vlan (if
configured). The guest vlan timer is only relevant when guest vlan has been configured
on that specific port.
The value, in seconds, of the timer used by the authenticator state machine on this port
to determine when re-authentication of the supplicant takes place. The reauth-period
must be a value in the range 1 - 65535.
The value, in seconds, of the timer used by the authenticator state machine on this port
to define periods of time in which it will not attempt to acquire a supplicant. The
quiet-period must be a value in the range 0 - 65535.
The value, in seconds, of the timer used by the authenticator state machine on this port
to determine when to send an EAPOL EAP Request/Identity frame to the supplicant. The
quiet-period must be a value in the range 1 - 65535.
The value, in seconds, of the timer used by the authenticator state machine on this port
to timeout the supplicant. The supp-timeout must be a value in the range 1 - 65535.
The value, in seconds, of the timer used by the authenticator state machine on this port
to timeout the authentication server. The supp-timeout must be a value in the range 1 -
65535.
Interface Config

Table of Contents

Other manuals for NETGEAR ProSAFE M7100-24X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSAFE M7100-24X and is the answer not in the manual?

NETGEAR ProSAFE M7100-24X Specifications

General IconGeneral
BrandNETGEAR
ModelProSAFE M7100-24X
CategorySwitch
LanguageEnglish

Related product manuals