EasyManua.ls Logo

NETGEAR ProSAFE M7100-24X - Sntp Server; Clock Timezone; Sntp Unicast Client Poll-Retry

NETGEAR ProSAFE M7100-24X
776 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Utility Commands
552
ProSafe Managed Switch
no sntp unicast client poll-timeout
This command will reset the poll timeout for SNTP unicast clients to its default value.
Format no sntp unicast client poll-timeout
Mode
sntp unicast client poll-retry
This command will set the poll retry for SNTP unicast clients to a value from 0 to 10.
Default
Format sntp unicast client poll-retry <poll-retry>
Mode
no sntp unicast client poll-retry
This command will reset the poll retry for SNTP unicast clients to its default value.
Format no sntp unicast client poll-retry
Mode
sntp server
This command configures an SNTP server (a maximum of three). The optional priority can be
a value of 1-3, the version a value of 1-4, and the port id a value of 1-65535.
Format sntp server <ipaddress|ipv6address| hostname> [<priority> [<version>
[<portid>]]]
Mode
no sntp server
This command deletes an server from the configured SNTP servers.
Format no sntp server remove <ipaddress|ipv6address| hostname>
Mode
clock timezone
When using SNTP/NTP time servers to update the switch’s clock, the time data received from
the server is based on Coordinated Universal Time (UTC) which is the same as Greenwich
Format sntp unicast client poll-timeout <poll-timeout>
Mode
Global Config
Global Config
1
Global Config
Global Config
Global Config
Global Config

Table of Contents