EasyManua.ls Logo

NETGEAR ProSAFE M7100-24X - Stacking

NETGEAR ProSAFE M7100-24X
776 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Log Messages
720
ProSafe Managed Switch
Stacking
Table 51. PIM-DM Log Messages
Component Message Cause
PIM-DM
Out of memory when creating xxx This message is logged when there is
insufficient memory to accommodate a new
neighbor/(S,G) Entry, Prune, Graft, Join
etc.
PIM-DM
Error entry->ll_xxx LL creation error This message is logged when the SLL
creation is Failed.
PIM-DM
pim_interface_set: Could not give
taskSema
This message is logged when Task
synchronization Semaphore release fails.
PIM-DM
Error initializing CACHE This message is logged when the PIM-DM
(S,G) entry Cache table initialization fails.
PIM-DM
Error creating PIM-DM pipe This message is logged when the PIM-DM
Pipe (that receives control messages)
creation fails.
Table 52. DVMRP Log Messages
Component Message Cause
DVMRP
dvmrp_send_graft: failed getting memory
for graft
Failed to allocate memory while sending a
graft
DVMRP
dvmrp_register_neighbor: failed getting
memory for nbr
Failed to allocate memory while registering
a neighbor
DVMRP
dvmrp_recv_prune: failed getting memory
for prune
Failed to allocate memory while receiving a
prune
DVMRP
dvmrp_new_route: failed getting memory
for route
Failed to get memory for a new route entry
DVMRP
dvmrp_prepare_routes: failed getting
memory for dvmrp_ann_rt
Failed to get memory while announcing a
new route entry
Table 53. EDB Log Message
Component Message Cause
EDB
EDB Callback: Unit Join: <num>. Unit <num> has joined the stack.