Utility Commands
541
ProSafe Managed Switch
Using the options described below, you can specify the initial and maximum time-to-live
(TTL) in probe packets, the maximum number of failures before termination, the number of
probes sent for each TTL, and the size of each probe.
ipaddr|hostname
initTtl
maxTtl
maxFail
interval
count
port
size
source
The following are examples of the CLI command.
traceroute Success:
(Switch) # traceroute 10.240.10.115 initTtl 1 maxTtl 4 maxFail 0 interval 1 count 3 port
33434 size 43
Traceroute to 10.240.10.115 ,4 hops max 43 byte packets:
1 10.240.4.1 708 msec 41 msec 11 msec
2 10.240.10.115 0 msec 0 msec 0 msec
Hop Count = 1 Last TTL = 2 Test attempt = 6 Test Success = 6
traceroute Failure:
(Switch) # traceroute 10.40.1.1 initTtl 1 maxFail 0 interval 1 count 3
port 33434 size 43
Traceroute to 10.40.1.1 ,30 hops max 43 byte packets:
1 10.240.4.1 19 msec 18 msec 9 msec
2 10.240.1.252 0 msec 0 msec 1 msec
3 172.31.0.9 277 msec 276 msec 277 msec
4 10.254.1.1 289 msec 327 msec 282 msec
5 10.254.21.2 287 msec 293 msec 296 msec
6 192.168.76.2 290 msec 291 msec 289 msec
7 0.0.0.0 0 msec *
Parameter Description
The ipaddr value should be a valid IP address. The hostname value should
be a valid hostname.
Use initTtl to specify the initial time-to-live (TTL), the maximum number of router
hops between the local and remote system. Range is 0 to 255.
Use maxTtle to specify the maximum TTL. Range is 1 to 255.
Use maxFail to terminate the traceroute after failing to receive a response for this
number of consecutive probes. Range is 0 to 255.
Use interval to specify the time between probes, in seconds. Range is 1 to 60
seconds.
Use the optional count parameter to specify the number of probes to send for each
TTL value. Range is 1 to 10 probes.
Use the optional port parameter to specify destination UDP port of the probe. This
should be an unused port on the remote destination system. Range is 1 to 65535.
Use the optional size parameter to specify the size, in bytes, of the payload of the
Echo Requests sent. Range is 0 to 65507 bytes.
Use the optional source parameter to specify the source IP address or interface for
the traceroute.